Espressif Systems /ESP32-S3 /MCPWM0 /TZ2_CFG0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as TZ2_CFG0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (TZ2_SW_CBC)TZ2_SW_CBC 0 (TZ2_F2_CBC)TZ2_F2_CBC 0 (TZ2_F1_CBC)TZ2_F1_CBC 0 (TZ2_F0_CBC)TZ2_F0_CBC 0 (TZ2_SW_OST)TZ2_SW_OST 0 (TZ2_F2_OST)TZ2_F2_OST 0 (TZ2_F1_OST)TZ2_F1_OST 0 (TZ2_F0_OST)TZ2_F0_OST 0TZ2_A_CBC_D 0TZ2_A_CBC_U 0TZ2_A_OST_D 0TZ2_A_OST_U 0TZ2_B_CBC_D 0TZ2_B_CBC_U 0TZ2_B_OST_D 0TZ2_B_OST_U

Description

Actions on PWM2A and PWM2B trip events

Fields

TZ2_SW_CBC

Enable register for software force cycle-by-cycle mode action. 0: disable, 1: enable

TZ2_F2_CBC

event_f2 will trigger cycle-by-cycle mode action. 0: disable, 1: enable

TZ2_F1_CBC

event_f1 will trigger cycle-by-cycle mode action. 0: disable, 1: enable

TZ2_F0_CBC

event_f0 will trigger cycle-by-cycle mode action. 0: disable, 1: enable

TZ2_SW_OST

Enable register for software force one-shot mode action. 0: disable, 1: enable

TZ2_F2_OST

event_f2 will trigger one-shot mode action. 0: disable, 1: enable

TZ2_F1_OST

event_f1 will trigger one-shot mode action. 0: disable, 1: enable

TZ2_F0_OST

event_f0 will trigger one-shot mode action. 0: disable, 1: enable

TZ2_A_CBC_D

Cycle-by-cycle mode action on PWM2A when fault event occurs and timer is decreasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_A_CBC_U

Cycle-by-cycle mode action on PWM2A when fault event occurs and timer is increasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_A_OST_D

One-shot mode action on PWM2A when fault event occurs and timer is decreasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_A_OST_U

One-shot mode action on PWM2A when fault event occurs and timer is increasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_B_CBC_D

Cycle-by-cycle mode action on PWM2B when fault event occurs and timer is decreasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_B_CBC_U

Cycle-by-cycle mode action on PWM2B when fault event occurs and timer is increasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_B_OST_D

One-shot mode action on PWM2B when fault event occurs and timer is decreasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle

TZ2_B_OST_U

One-shot mode action on PWM2B when fault event occurs and timer is increasing. 0: do nothing, 1: force lo, 2: force hi, 3: toggle